    1 # Example sentinel.conf
    2 
    3 # By default protected mode is disabled in sentinel mode. Sentinel is reachable
    4 # from interfaces different than localhost. Make sure the sentinel instance is
    5 # protected from the outside world via firewalling or other means.
    6 protected-mode no
    7 
    8 # port <sentinel-port>
    9 # The port that this sentinel instance will run on
   10 port 26379
   11 
   12 # By default Redis Sentinel does not run as a daemon. Use 'yes' if you need it.
   13 # Note that Redis will write a pid file in /var/run/redis-sentinel.pid when
   14 # daemonized.
   15 daemonize no
   16 
   17 # When running daemonized, Redis Sentinel writes a pid file in
   18 # /var/run/redis-sentinel.pid by default. You can specify a custom pid file
   19 # location here.
   20 pidfile /var/run/redis-sentinel.pid
   21 
   22 # Specify the log file name. Also the empty string can be used to force
   23 # Sentinel to log on the standard output. Note that if you use standard
   24 # output for logging but daemonize, logs will be sent to /dev/null
   25 logfile ""
   26 
   27 # sentinel announce-ip <ip>
   28 # sentinel announce-port <port>
   29 #
   30 # The above two configuration directives are useful in environments where,
   31 # because of NAT, Sentinel is reachable from outside via a non-local address.
   32 #
   33 # When announce-ip is provided, the Sentinel will claim the specified IP address
   34 # in HELLO messages used to gossip its presence, instead of auto-detecting the
   35 # local address as it usually does.
   36 #
   37 # Similarly when announce-port is provided and is valid and non-zero, Sentinel
   38 # will announce the specified TCP port.
   39 #
   40 # The two options don't need to be used together, if only announce-ip is
   41 # provided, the Sentinel will announce the specified IP and the server port
   42 # as specified by the "port" option. If only announce-port is provided, the
   43 # Sentinel will announce the auto-detected local IP and the specified port.
   44 #
   45 # Example:
   46 #
   47 # sentinel announce-ip 1.2.3.4
   48 
   49 # dir <working-directory>
   50 # Every long running process should have a well-defined working directory.
   51 # For Redis Sentinel to chdir to /tmp at startup is the simplest thing
   52 # for the process to don't interfere with administrative tasks such as
   53 # unmounting filesystems.
   54 dir /tmp
   55 
   56 # sentinel monitor <master-name> <ip> <redis-port> <quorum>
   57 #
   58 # Tells Sentinel to monitor this master, and to consider it in O_DOWN
   59 # (Objectively Down) state only if at least <quorum> sentinels agree.
   60 #
   61 # Note that whatever is the ODOWN quorum, a Sentinel will require to
   62 # be elected by the majority of the known Sentinels in order to
   63 # start a failover, so no failover can be performed in minority.
   64 #
   65 # Replicas are auto-discovered, so you don't need to specify replicas in
   66 # any way. Sentinel itself will rewrite this configuration file adding
   67 # the replicas using additional configuration options.
   68 # Also note that the configuration file is rewritten when a
   69 # replica is promoted to master.
   70 #
   71 # Note: master name should not include special characters or spaces.
   72 # The valid charset is A-z 0-9 and the three characters ".-_".
   73 sentinel monitor mymaster 127.0.0.1 6379 2
   74 
   75 # sentinel auth-pass <master-name> <password>
   76 #
   77 # Set the password to use to authenticate with the master and replicas.
   78 # Useful if there is a password set in the Redis instances to monitor.
   79 #
   80 # Note that the master password is also used for replicas, so it is not
   81 # possible to set a different password in masters and replicas instances
   82 # if you want to be able to monitor these instances with Sentinel.
   83 #
   84 # However you can have Redis instances without the authentication enabled
   85 # mixed with Redis instances requiring the authentication (as long as the
   86 # password set is the same for all the instances requiring the password) as
   87 # the AUTH command will have no effect in Redis instances with authentication
   88 # switched off.
   89 #
   90 # Example:
   91 #
   92 # sentinel auth-pass mymaster MySUPER--secret-0123passw0rd
   93 
   94 # sentinel auth-user <master-name> <username>
   95 #
   96 # This is useful in order to authenticate to instances having ACL capabilities,
   97 # that is, running Redis 6.0 or greater. When just auth-pass is provided the
   98 # Sentinel instance will authenticate to Redis using the old "AUTH <pass>"
   99 # method. When also an username is provided, it will use "AUTH <user> <pass>".
  100 # In the Redis servers side, the ACL to provide just minimal access to
  101 # Sentinel instances, should be configured along the following lines:
  102 #
  103 #     user sentinel-user >somepassword +client +subscribe +publish \
  104 #                        +ping +info +multi +slaveof +config +client +exec on
  105 
  106 # sentinel down-after-milliseconds <master-name> <milliseconds>
  107 #
  108 # Number of milliseconds the master (or any attached replica or sentinel) should
  109 # be unreachable (as in, not acceptable reply to PING, continuously, for the
  110 # specified period) in order to consider it in S_DOWN state (Subjectively
  111 # Down).
  112 #
  113 # Default is 30 seconds.
  114 sentinel down-after-milliseconds mymaster 30000
  115 
  116 # IMPORTANT NOTE: starting with Redis 6.2 ACL capability is supported for
  117 # Sentinel mode, please refer to the Redis website https://redis.io/topics/acl
  118 # for more details.
  119 
  120 # Sentinel's ACL users are defined in the following format:
  121 #
  122 #   user <username> ... acl rules ...
  123 #
  124 # For example:
  125 #
  126 #   user worker +@admin +@connection ~* on >ffa9203c493aa99
  127 #
  128 # For more information about ACL configuration please refer to the Redis
  129 # website at https://redis.io/topics/acl and redis server configuration 
  130 # template redis.conf.
  131 
  132 # ACL LOG
  133 #
  134 # The ACL Log tracks failed commands and authentication events associated
  135 # with ACLs. The ACL Log is useful to troubleshoot failed commands blocked 
  136 # by ACLs. The ACL Log is stored in memory. You can reclaim memory with 
  137 # ACL LOG RESET. Define the maximum entry length of the ACL Log below.
  138 acllog-max-len 128
  139 
  140 # Using an external ACL file
  141 #
  142 # Instead of configuring users here in this file, it is possible to use
  143 # a stand-alone file just listing users. The two methods cannot be mixed:
  144 # if you configure users here and at the same time you activate the external
  145 # ACL file, the server will refuse to start.
  146 #
  147 # The format of the external ACL user file is exactly the same as the
  148 # format that is used inside redis.conf to describe users.
  149 #
  150 # aclfile /etc/redis/sentinel-users.acl
  151 
  152 # requirepass <password>
  153 #
  154 # You can configure Sentinel itself to require a password, however when doing
  155 # so Sentinel will try to authenticate with the same password to all the
  156 # other Sentinels. So you need to configure all your Sentinels in a given
  157 # group with the same "requirepass" password. Check the following documentation
  158 # for more info: https://redis.io/topics/sentinel
  159 #
  160 # IMPORTANT NOTE: starting with Redis 6.2 "requirepass" is a compatibility
  161 # layer on top of the ACL system. The option effect will be just setting
  162 # the password for the default user. Clients will still authenticate using
  163 # AUTH <password> as usually, or more explicitly with AUTH default <password>
  164 # if they follow the new protocol: both will work.
  165 #
  166 # New config files are advised to use separate authentication control for
  167 # incoming connections (via ACL), and for outgoing connections (via
  168 # sentinel-user and sentinel-pass) 
  169 #
  170 # The requirepass is not compatible with aclfile option and the ACL LOAD
  171 # command, these will cause requirepass to be ignored.
  172 
  173 # sentinel sentinel-user <username>
  174 #
  175 # You can configure Sentinel to authenticate with other Sentinels with specific
  176 # user name. 
  177 
  178 # sentinel sentinel-pass <password>
  179 #
  180 # The password for Sentinel to authenticate with other Sentinels. If sentinel-user
  181 # is not configured, Sentinel will use 'default' user with sentinel-pass to authenticate.
  182 
  183 # sentinel parallel-syncs <master-name> <numreplicas>
  184 #
  185 # How many replicas we can reconfigure to point to the new replica simultaneously
  186 # during the failover. Use a low number if you use the replicas to serve query
  187 # to avoid that all the replicas will be unreachable at about the same
  188 # time while performing the synchronization with the master.
  189 sentinel parallel-syncs mymaster 1
  190 
  191 # sentinel failover-timeout <master-name> <milliseconds>
  192 #
  193 # Specifies the failover timeout in milliseconds. It is used in many ways:
  194 #
  195 # - The time needed to re-start a failover after a previous failover was
  196 #   already tried against the same master by a given Sentinel, is two
  197 #   times the failover timeout.
  198 #
  199 # - The time needed for a replica replicating to a wrong master according
  200 #   to a Sentinel current configuration, to be forced to replicate
  201 #   with the right master, is exactly the failover timeout (counting since
  202 #   the moment a Sentinel detected the misconfiguration).
  203 #
  204 # - The time needed to cancel a failover that is already in progress but
  205 #   did not produced any configuration change (SLAVEOF NO ONE yet not
  206 #   acknowledged by the promoted replica).
  207 #
  208 # - The maximum time a failover in progress waits for all the replicas to be
  209 #   reconfigured as replicas of the new master. However even after this time
  210 #   the replicas will be reconfigured by the Sentinels anyway, but not with
  211 #   the exact parallel-syncs progression as specified.
  212 #
  213 # Default is 3 minutes.
  214 sentinel failover-timeout mymaster 180000
  215 
  216 # SCRIPTS EXECUTION
  217 #
  218 # sentinel notification-script and sentinel reconfig-script are used in order
  219 # to configure scripts that are called to notify the system administrator
  220 # or to reconfigure clients after a failover. The scripts are executed
  221 # with the following rules for error handling:
  222 #
  223 # If script exits with "1" the execution is retried later (up to a maximum
  224 # number of times currently set to 10).
  225 #
  226 # If script exits with "2" (or an higher value) the script execution is
  227 # not retried.
  228 #
  229 # If script terminates because it receives a signal the behavior is the same
  230 # as exit code 1.
  231 #
  232 # A script has a maximum running time of 60 seconds. After this limit is
  233 # reached the script is terminated with a SIGKILL and the execution retried.
  234 
  235 # NOTIFICATION SCRIPT
  236 #
  237 # sentinel notification-script <master-name> <script-path>
  238 # 
  239 # Call the specified notification script for any sentinel event that is
  240 # generated in the WARNING level (for instance -sdown, -odown, and so forth).
  241 # This script should notify the system administrator via email, SMS, or any
  242 # other messaging system, that there is something wrong with the monitored
  243 # Redis systems.
  244 #
  245 # The script is called with just two arguments: the first is the event type
  246 # and the second the event description.
  247 #
  248 # The script must exist and be executable in order for sentinel to start if
  249 # this option is provided.
  250 #
  251 # Example:
  252 #
  253 # sentinel notification-script mymaster /var/redis/notify.sh
  254 
  255 # CLIENTS RECONFIGURATION SCRIPT
  256 #
  257 # sentinel client-reconfig-script <master-name> <script-path>
  258 #
  259 # When the master changed because of a failover a script can be called in
  260 # order to perform application-specific tasks to notify the clients that the
  261 # configuration has changed and the master is at a different address.
  262 # 
  263 # The following arguments are passed to the script:
  264 #
  265 # <master-name> <role> <state> <from-ip> <from-port> <to-ip> <to-port>
  266 #
  267 # <state> is currently always "start"
  268 # <role> is either "leader" or "observer"
  269 # 
  270 # The arguments from-ip, from-port, to-ip, to-port are used to communicate
  271 # the old address of the master and the new address of the elected replica
  272 # (now a master).
  273 #
  274 # This script should be resistant to multiple invocations.
  275 #
  276 # Example:
  277 #
  278 # sentinel client-reconfig-script mymaster /var/redis/reconfig.sh
  279 
  280 # SECURITY
  281 #
  282 # By default SENTINEL SET will not be able to change the notification-script
  283 # and client-reconfig-script at runtime. This avoids a trivial security issue
  284 # where clients can set the script to anything and trigger a failover in order
  285 # to get the program executed.
  286 
  287 sentinel deny-scripts-reconfig yes
  288 
  289 # REDIS COMMANDS RENAMING (DEPRECATED)
  290 #
  291 # WARNING: avoid using this option if possible, instead use ACLs.
  292 #
  293 # Sometimes the Redis server has certain commands, that are needed for Sentinel
  294 # to work correctly, renamed to unguessable strings. This is often the case
  295 # of CONFIG and SLAVEOF in the context of providers that provide Redis as
  296 # a service, and don't want the customers to reconfigure the instances outside
  297 # of the administration console.
  298 #
  299 # In such case it is possible to tell Sentinel to use different command names
  300 # instead of the normal ones. For example if the master "mymaster", and the
  301 # associated replicas, have "CONFIG" all renamed to "GUESSME", I could use:
  302 #
  303 # SENTINEL rename-command mymaster CONFIG GUESSME
  304 #
  305 # After such configuration is set, every time Sentinel would use CONFIG it will
  306 # use GUESSME instead. Note that there is no actual need to respect the command
  307 # case, so writing "config guessme" is the same in the example above.
  308 #
  309 # SENTINEL SET can also be used in order to perform this configuration at runtime.
  310 #
  311 # In order to set a command back to its original name (undo the renaming), it
  312 # is possible to just rename a command to itself:
  313 #
  314 # SENTINEL rename-command mymaster CONFIG CONFIG
  315 
  316 # HOSTNAMES SUPPORT
  317 #
  318 # Normally Sentinel uses only IP addresses and requires SENTINEL MONITOR
  319 # to specify an IP address. Also, it requires the Redis replica-announce-ip
  320 # keyword to specify only IP addresses.
  321 #
  322 # You may enable hostnames support by enabling resolve-hostnames. Note
  323 # that you must make sure your DNS is configured properly and that DNS
  324 # resolution does not introduce very long delays.
  325 #
  326 SENTINEL resolve-hostnames no
  327 
  328 # When resolve-hostnames is enabled, Sentinel still uses IP addresses
  329 # when exposing instances to users, configuration files, etc. If you want
  330 # to retain the hostnames when announced, enable announce-hostnames below.
  331 #
  332 SENTINEL announce-hostnames no
  333 
  334 # When master_reboot_down_after_period is set to 0, Sentinel does not fail over
  335 # when receiving a -LOADING response from a master. This was the only supported
  336 # behavior before version 7.0.
  337 #
  338 # Otherwise, Sentinel will use this value as the time (in ms) it is willing to
  339 # accept a -LOADING response after a master has been rebooted, before failing
  340 # over.