As a special service "Fossies" has tried to format the requested source page into HTML format (assuming markdown format). Alternatively you can here view or download the uninterpreted source code file. A member file download can also be achieved by clicking within a package contents listing on the according byte size field.

POWERPANEL(8)

NAME

powerpanel - Driver for PowerPanel Plus compatible UPS equipment

NOTE

This man page only documents the hardware-specific features of the powerpanel driver. For information about the core driver, see linkman:nutupsdrv[8].

SUPPORTED HARDWARE

This driver supports CyberPower BC1200, PR2200 and many other similar devices, both for the text and binary protocols. The driver will autodetect which protocol is used.

EXTRA ARGUMENTS

This driver supports the following optional settings in linkman:ups.conf[5]:

protocol=[‘text,binary’]:: Override the default autodetection of the protocol.

manufacturer=‘value’:: If you don’t like the autodetected value, you can override this by setting it here.

model=‘value’:: Like manufacturer above.

serial=‘value’:: Like manufacturer above.

ondelay=‘value’:: Time to wait before switching on the UPS (1 - 9999 minutes, 0=indefinite). Only available with the text protocol driver (see <<_support_status,Support Status>>).

offdelay=‘value’:: Time to wait before shutting down the UPS (6 - 600 seconds). Values below 60 seconds will be truncated to 6 seconds intervals, values above 60 seconds to 60 seconds intervals. Only available with the text protocol driver (see <<_support_status,Support Status>>).

VARIABLES

Depending on the type of your UPS unit, some of the following variables may be changed with linkman:upsrw[8]. If the driver can’t read a variable from the UPS, it will not be made available.

input.transfer.high:: writable: high transfer voltage point in V

input.transfer.low:: writable: low transfer voltage point in V

battery.charge.low:: writable: remaining battery charge percentage for low battery warning

output.voltage.nominal:: writable: nominal output voltage in V

ups.start.battery:: writable: allow cold start from battery

COMMANDS

Depending on the type of your UPS unit, some of the following commands may be available.

On many devices, these commands are unreliable, so before using them you must verify that these work as expected (see <<_shutdown_issues,Shutdown Issues>>).

SUPPORT STATUS

Vendor support is absent for this driver, so if you need some features that are currently not available, provide ample documentation on what the driver should sent to the UPS in order to make this work. If more information would be available on the binary protocol, it would probably be possible to make ‘ondelay’ and ‘offdelay’ configurable. So far, nobody has taken the time to investigate what we should tell the UPS to make this work, and CyberPower isn’t willing to share this with us.

SHUTDOWN ISSUES

If the shutdown.return command on your UPS doesn’t seem to work, chances are that your UPS is an older model. Try a couple of different settings for ‘offdelay’. If no value in the range 6..600 works, your UPS likely doesn’t support this. In order to get the expected behaviour, it requires shutdown.stayoff (when on battery) and shutdown.reboot (when on mains). The driver will automatically fallback to these commands if shutdown.return fails, and tries to detect which one should be used when called with the ‘-k’ option (or through upsdrvctl shutdown).

This isn’t bullet-proof, however, and you should be prepared that the power will either not be shutdown or that it doesn’t return when the power comes back. All models supported by the binary protocol and many supported through the text protocol are affected by this.

KNOWN PROBLEMS

The CyberPower OP series don’t offer direct voltage, charge, frequency and temperature readings. Instead, they will return a binary value that needs conversion to the actual value.

The exact conversion needed is unknown at the time of this writing, hence an estimation was made based om readings from actual devices. This may (probably will) be off, possibly a lot. Unless you can tell us the exact mapping between values from the UPS and actual readings, don’t bother to complain. We’ve done the best we can based on the limited information available. Remember, a UPS isn’t a measuring instrument.

AUTHORS

Arjen de Korte arjen@de-korte.org, Doug Reynolds mav@wastegate.net

SEE ALSO

The core driver: ~~~~~~~~~~~~~~~~ linkman:nutupsdrv[8]

Internet resources: ~~~~~~~~~~~~~~~~~~~ The NUT (Network UPS Tools) home page: http://www.networkupstools.org/